MX500 W Shipyard
Model
2No models found.
Description
Strong and reliable solution
MX500 Shipyard is welder friendly with its simple and intuitive interface. It provides the possibility to apply gas metal arc (MIG/MAG), argon (TIG), and coated electrode (MMA) processes in a single machine. With its durable and functional design, it can be used safely in all kinds of harsh working conditions.
Welder-friendly operation
The MX500 Shipyard offers an intuitive interface that highlights the settings users use most frequently. Thanks to its effortless and user-friendly interface, it is designed to reduce the need for trained welders.
Synergic interface
The MX500 Shipyard features an exceptionally intuitive Optional Synergic interface that highlights the parameters most frequently used by operators. Its effortless, user-friendly design minimizes setup time and significantly reduces the need for highly trained welders, enabling faster onboarding and consistently high welding quality.
Experience 450 welding program
MX500 Shipyard has 450 welding programs that facilitate the welding of steel, stainless steel, aluminum, copper, and zinc alloys, eliminating spatter and the need for post-weld grinding, and it has a memory capacity of 99 programs.
Advanced function table
Function table for MIG/MAG, TIG and MMA welding, allowing advanced settings to be adjusted as needed. Maximizes the welding experience.
High welding speed, low heat input
Synergic keeps the voltage constant after droplet transfer by rapidly reducing the welding current vertically to a certain reference level. This increases the welding speed, resulting in low heat input and an intensified arc.
4x4 wire feeder unit
With 4 channels and 4-groove, 32 mm ball-bearing wire feed rollers, a strong grip is provided to the wire without damaging its physical form. This feature enables uninterrupted wire feeding while eliminating wire breakage issues.
256 PPR optical counter
By controlling the wire speed 50.000 times per second, it ensures that the welding wire reaches the weld pool at a constant rate. This feature minimizes the impact of conditions that negatively affect wire feeding speed on the weld, such as torch bending, contamination in the wire path, and narrowing of the contact tip diameter.
Military standard connector
It offers durability, sealing, protection against electromagnetic interference, high transmission performance and easy removal and installation.
Smart cooling
Intelligent cooling fan technology, which is only activated when needed, reduces noise, dust accumulation inside the machine and energy consumption. Increases cooling fan and fluid pump life up to 7 times.
Hose pack support
Hose supports on the wire feed unit and trolley prevent the outer sheath from being stripped off during movement. Easily removable, these hose supports ensure that power, communication, gas and water connectors are securely attached to the machine.
MX500 Shipyard
| ERR | 01 | Error-1 Phase error. Occurs when any of the phases does not reach the machine. |
| ERR | 03 | Error-3 IGBT thermal error. Occurs when the IGBTs overheat or when the fan is not operating. (Used in SAW models only.) |
| ERR | 04 | Error-4 Flow sensor error. Triggered when the machine runs out of coolant or when the connectors are not properly inserted. |
| ERR | 05 | Error-5 IGBT thermal error. Occurs when the IGBTs overheat or the fan is not operating. |
| ERR | 06 | Error-6 Diode thermal error. Triggered when the output diode overheats. |
| ERR | 08 | Error-8 Panel board communication error. Occurs when the panel board fails to communicate with the motor board. |
| ERR | 09 | Error-9 Motor board communication error. Occurs when the motor board fails to communicate with the control board. |
| ERR | 10 | Error-10 Con trol board communication error. Triggered when the control board fails to communicate with the panel. |
| ERR | 12 | Error-12 Overcurrent error. Occurs when the machine attempts to draw excessive current or when one of the phases is missing. |
| ERR | 14 | Error-14 Overcurrent protection error. Usually triggered by an IGBT malfunction. |
| ERR | 15 | Error-15 It occurs when there is a problem at +15 or -5 volts. It can also trigger this error if the current sensor is faulty. |
| ERR | 20 | Error-20 Robot board communication error. Occurs when the robot board fails to communicate with the control board. |
| ERR | 30 | Error-30 Motor overcurrent error. Triggered when the motor current exceeds its defined limit. |
| ERR | 40 | Error-40 Memory read/write error. Occurs when the panel fails to read or write data. When this error occurs, the panel automatically resets after 5 seconds and attempts to read/write again. |
- Input Voltage: 400 V
- Mains Voltage Tolerance: -10 /+15 %
- Minimum Welding Current: 10 A
- Maximum Welding Current: 500 A
- Duty Cycle, 40°C: MIG 500A 60%, TIG 500A 60%, MMA 500A 60% | MIG 400A 100%, TIG 400A 100%, MMA 400A 100%
- Open – Circuit Voltage: 63 V – 82 V
- Factory Delivered Roller: 1.0 + 1.2 mm / Steel
- Weight: Air-Cooled | 92 kg
Technical documentation: Manuals or product documents are available for this model.
Available Variants
2| Product | Model | Price | Stock | Quantity | Action |
|---|---|---|---|---|---|
MX500 Shipyard
Code: MX500 Shipyard
Model
MX500 Shipyard
|
MX500 Shipyard
|
Price on request | Availability to be confirmed |
|
|
MX500 W Shipyard
Code: MX500 W Shipyard
Current
Model
MX500 W Shipyard
|
MX500 W Shipyard
|
Price on request | Availability to be confirmed |
|